Cyclercheck – control system

False negative PCR results are highly critical and might be due to a defective PCR cycler.

Cyclercheck kit is a validation tool for conventional PCR cyclers according to legal requirements. Each well of the thermoblock wil be checked: Temperature – Heating – Cooling – Ramp Rate – Annealing – Elongation.

Applicable to any block PCR cycler in research or industrial quality control to test the legal requirements for testing the reliability of instruments used for analysis (ISO 17025, EN 45001, ISO 13485, GLP, GMP).

No extra equipment, instrument or software needed. The kit includes all you need.

Area:

Technology:

Brand:

Documents:

Consult our experts

Google reCaptcha: Invalid site key.

Related products

NimoTest® Fetal RHD qPCR kit

NIMoTest® Fetal RHD qPCR kit is a kit for determining the fetal RHD genotype from maternal plasma. It is intended for the monitoring of RhD-negative pregnant women to guide anti-RhD immunoprophylaxis and adapt the monitoring of immunised women. Detailed description The kit is designed for duplex quantitative PCR (pPCR) amplification of exons 5 and 7…
BeDia Genomics
Real Time PCR (qPCR)

Genvinset® MTHFR multiplex

In vitro diagnostic kit based on real-time PCR for the simultaneous detection of the A1298C and C677T polymorphisms in the MTHFR gene. Detailed description Operating principle The assay is based on real-time PCR (Real-Time PCR) amplification using TaqMan® hydrolysis probes. Two primer pairs are used to amplify specific regions of the MTHFR gene containing the…
Blackhills Diagnostic Resources
Real Time PCR (qPCR)

Genvinset® FIIFV multiplex

In vitro diagnostic kit for the simultaneous detection of the G20210A mutation in the prothrombin gene (FII) and the G1691A mutation in Factor V using real-time PCR. Detailed description Operating principle The assay is based on the real-time PCR (Real-Time PCR) amplification of specific regions of the FII and FV factor genes containing the mutations…
Blackhills Diagnostic Resources
Real Time PCR (qPCR)

Genvinset® PAI-1/FXIII multiplex

In vitro diagnostic kit based on real-time PCR for the simultaneous detection of the -675 PAI-1 4G/5G polymorphism in the SERPINE1 gene and rs5985 (Val34Leu) in the F13A1 gene, associated with the risk of thrombosis. Detailed description Operating principle Genvinset® PAI-1/FXIII multiplex uses real-time PCR technology (Real-Time PCR) with TaqMan® hydrolysis probes for the qualitative…